"See the Invisible Threats"
Distributed IoT sensor network with AI-powered analytics. OFIL Corona detection, OGI gas imaging, ice monitoring, and Dynamic Line Rating — all integrated into GridGuardian for unified grid visibility.
Without real-time visibility, utilities react to failures instead of preventing them.
Invisible electrical faults degrade insulators and equipment. Without UV detection, failures happen without warning.
SF6 is 23,500x more potent than CO2. Substations leak thousands of tons annually. Invisible to the naked eye.
$2.7B annual weather-related outage costs. No early warning for ice accumulation on transmission lines.
Advanced sensors for comprehensive grid monitoring — from corona discharge to ice accumulation.
"See the Invisible Discharge"
Solar-blind UV technology (DayCor®) enables precise, real-time detection of corona partial discharges and arcing in full daylight. Identify failing insulators, damaged conductors, and faulty connections before they cause outages. Industry-leading sensitivity at 1pC @ 12m.
| Technical Specifications | |
|---|---|
| Technology | Solar-blind UV (DayCor®) — below 280nm |
| Detection | Corona, Partial Discharge, Arcing |
| Sensitivity | 1 pC @ 12m (Eurotest certified) |
| Range | 50-70 meters safe inspection distance |
| Operation | Full daylight, no sun interference |
| Platforms | Handheld, Drone, Helicopter, Fixed |
"Visualize the Invisible Leaks"
Optical Gas Imaging cameras use specialized infrared technology to detect and visualize fugitive gas emissions in real-time. See methane, SF6, VOCs, and 400+ industrial gases as visible smoke plumes. Essential for substation SF6 monitoring and environmental compliance.
| Technical Specifications | |
|---|---|
| Technology | MWIR Infrared (3-5µm spectrum) |
| Detectable Gases | Methane, SF6, VOCs, 400+ compounds |
| Sensitivity | 0.28 kg/h @ 91% probability |
| Resolution | 640 x 512 HD thermal imaging |
| Compliance | EPA OOOOa/b/c, OGMP 2.0 Level 5 |
| Operation | 24/7 continuous or portable inspection |
"Prevent Before the Storm"
Real-time ice accumulation monitoring for transmission lines. Capacitive sensors, AI-powered cameras, and fiber optic systems detect early-stage ice buildup before it compromises safety. Proven in extreme climates: Norway, Canada, Iceland. Line-powered, satellite-connected.
| Technical Specifications | |
|---|---|
| Technology | Capacitive + Optical + FBG sensors |
| Measurements | Ice thickness, sag, tension, temperature |
| Accuracy | RMSE 1.20mm, 98.35% detection rate |
| Power | Line-powered (self-sufficient) |
| Communication | Satellite / LTE / LoRa |
| Environment | -40°C to +60°C, IP67 |
"Maximize Grid Capacity"
Dynamic Line Rating systems measure real-time conductor temperature, ambient conditions, and wind speed to calculate actual transmission capacity. Unlock 10-30% additional capacity over static ratings without infrastructure upgrades. FERC Order 881 compliant.
| Technical Specifications | |
|---|---|
| Measurements | Conductor temp, ambient, wind, solar |
| Capacity Gain | 10-30% over static rating |
| Update Rate | Real-time (1-15 minute intervals) |
| Compliance | FERC Order 881, IEEE 738 |
| Integration | SCADA, EMS, market systems |
| ROI | Deferred capital, congestion relief |
Real results from SensorGuard deployments worldwide.